Hydrotechnik home

DATA SHEETS
Sensors
QT 3xx Data Sheet

Pressure Sensor HySense® QT 300

The turbine volume flow meter HySense® QT functions according to the flow principle. A medium flow through a tube in an axial direction and makes the turbine wheel turning. The single turns are caught by a signal pick-up which changes the signals in digital impulses. HySense® QT turbine volume flow meters are available in different measurement ranges from 1 until 1000 l/min.


Your benefit at a glance:

QT 3xx more information here
  •    -  Easy to handle: Good reliability, low error limits
  •    -  Easy to install
  •    -  Low energy loss, long life
  •    -  Real-time information
  •    -  Short response time
  •    -  Linearisation in the measuring instrument
  •    -  Low flow resistance, suitable for lots of media
  •    -  High media temperature and working pressure up to 5801 psi
  •    -  Small delta-P (differential pressure)
  •    -  Media viscosity up 1 to 100 mm2/s (cSt)
  •    -  IP 67

Technical:

QT 300 Frequency (ISDS)
  •    -  Circular connectors M16 x 0.75 with screw-locking Layout 06-a, 6 poles, male IEC / DIN EN 61076-2-106
QT 310 4…20 mA 2-wire (ISDS)
  •    -  Circular connectors M16 x 0.75 with screw-locking Layout 06-a, 6 poles, male IEC / DIN EN 61076-2-106
QT 106 CAN
  •    -  Circular connectors M12 x 1 with screw-locking A-coding, 5 poles, male IEC / DIN EN 61076-2-101


Design size Connection thread Length Pipe Ø Max. pressure  Weight
    mm mm Bar PSI g
QT 3xx 1000L 2“-SAE-Flange 256 67 420 6000 ca. 11440

Part Number Accessories and Spare Parts 
8824-S1-02.50S Measuring cable frequency / 4…20mA / ISDS (standard) For turbine 31V7-… and 31G7-... with and without ISDS, IP40, max. traction 160N, 2.5 m M16 6-pole connector – 6-pole M16 socket
8824-S1-02.50H Measuring cable frequency / 4…20mA / ISDS (standard) For turbine 31V7-… and 31G7-... with and without ISDS, IP67, max. traction 300N, 2.5 m, M16 6-pole connector – 6-pole M16 socket
8824-M5-02.50 Measuring cable CAN for MS 5060 For CAN turbine 31C7-…, M12 5-pole socket – M12 8-pole connector
8824-R7-02.50 Measuring cable CAN for MS 4010 and 5060plus For CAN turbine 31C7-…, M12 5-pole socket – M12 8-pole connector
8824-S4-00.20 Measuring cable double signal connection for frequency output For turbine with direction detection 31D7-... with and without ISDS
8824-I4-00.00 Measuring cable 4…20mA M12x1 5-pol. For turbine with IP67 and current output 31E7-…
3763-03-34.00 p/T Sensor pressure / temperature sensor HySense TP 180, 4…20mA, IP40, 0…60 MPa
3403-18-C3.37 Pressure sensor HySense PR 110, 4…20mA, IP67, 0…60 MPa
34P3-18-01.37A2 Pressure sensor HySense PR 410, 4…20mA, IP67, 0…60 MPa
3969-04-01.00S Temperature sensor HySense TE 110, 4…20mA, IP67, -50…+200°C
2103-07-18.62N Direct connection straight MINIMESS® series 1620, ISO228-G ¼“ female
2103-30-18.10N Coupling with plastic cap MINIMESS® series 1620, ISO228-G ¼“ female
31W7-00-09.00 Inductive sensor HySense RS 210, frequency output, IP67, M14x1
31W7-00-S-09.00 Inductive sensor with ISDS HySense RS 200 ISDS, frequency output, IP67, M14x1
31W7-00-26.00 Inductive sensor with current output HySense RS 210, current output 4…20mA, IP54, M14x1
31W7-00-S-26.00 Inductive sensor with current output and ISDS HySense RS 200 ISDS, current output 4…20mA, IP54, M14x1