Hydrotechnik home

DATA SHEETS
Sensors
QG1xx Data Sheet

Flow Volume Sensor HySense® QG 100 / 110

Gearwheels are set in motion via a medium. With each rotation of the gearwheels, a defined amount of liquid is transferred through the volume flow sensor. The rotation movements of the gearwheels are caught by signal pick-ups and transferred in digital impulses. QG100 has a frequency output. QG110 is delivered with an f/I-converter for analogue output signal 4...20 mA***G

Your benefit at a glance:

QG 1xx more information here
  •    -  Outstanding measuring accuracy, low error limits
  •    -  High viscosity independance, broad measuring range for each type
  •    -  High medium temperatures and working pressures up to 9137 psi
  •    -  Linearisation in the measuring instrument
  •    -  Detection of flow direction, arbitrary mounting position and connectors
  •    -  Measuring of quantities possible (metering)
  •    -  Viscosity min. 5 mm2/s (cSt)
  •    -  High measuring accuracy

Technical:

QG 100 Frequency (ISDS)
  •    -  Circular connectors M16 x 0.75 with screw-locking Layout 06-a, 6 poles, male IEC / DIN EN 61076-2-106
QG 110 4…20 mA 2-wire (ISDS)
  •    -  Circular connectors M16 x 0.75 with screw-locking Layout 06-a, 6 poles, male IEC / DIN EN 61076-2-106

Design size Measuring Range ØD Geometric tooth volume Max. pressure  Connection Weight
  l/min mm cm³ Bar   kg
3143-01-35.030 0.005…1 84 ca. 0.021 420 ISO 228-G1/4 1.6
3143-02-35.030 0.05…5 96 ca. 0.191 630 ISO 228-G1/4 2.7
3143-03-35.030 0.2…30 106 ca. 0.609 630 ISO 228-G3/8 3.6
3143-04-35.030 0.7…70 136 ca. 2.222 420 ISO 228-G3/4 8.5
3143-05-35.030 3.0…300 210 ca. 8.750 420 SAE 228-G1 1/4 32
3185-01-35.030 0.005…1 84 ca. 0.021 420 ISO 228-G1/4 1.6
3185-02-35.030 0.05…5 96 ca. 0.191 630 ISO 228-G1/4 2.7
3185-03-35.030 0.2…30 106 ca. 0.609 630 ISO 228-G3/8 3.6
3185-04-35.030 0.7…70 136 ca. 2.222 420 ISO 228-G3/4 8.5
3185-05-35.030 3.0…300 210 ca. 8.750 420 SAE 228-G1 1/4 32

Part Number Accessories and Spare Parts 
8824-S1-02.50S Measuring cable frequency / 4…20mA / ISDS (standard) For turbine 31V7-… and 31G7-... with and without ISDS, IP40, max. traction 160N, 2.5 m M16 6-pole connector – 6-pole M16 socket
8824-S1-02.50H Measuring cable frequency / 4…20mA / ISDS (standard) For turbine 31V7-… and 31G7-... with and without ISDS, IP67, max. traction 300N, 2.5 m, M16 6-pole connector – 6-pole M16 socket
3763-03-34.00 p/T Sensor pressure / temperature sensor HySense TP 180, 4…20mA, IP40, 0…60 MPa
3403-18-C3.37 Pressure sensor HySense PR 110, 4…20mA, IP67, 0…60 MPa
34P3-18-01.37A2 Pressure sensor HySense PR 410, 4…20mA, IP67, 0…60 MPa
3969-04-01.00S Temperature sensor HySense TE 110, 4…20mA, IP67, -50…+200°C
3107-00-45.00 Sensor with frequency output Spare part for QG 100 and QG 110