Hydrotechnik home

DATA SHEETS
Sensors
QG1xx Data Sheet

Flow Volume Sensor HySense® QG 100 / 110

Gearwheels are set in motion via a medium. With each rotation of the gearwheels, a defined amount of liquid is transferred through the volume flow sensor. The rotation movements of the gearwheels are caught by signal pick-ups and transferred in digital impulses. QG100 has a frequency output. QG110 is delivered with an f/I-converter for analogue output signal 4...20 mA***G

Your benefit at a glance:

  •    -  outstanding measuring accuracy, low error limits
  •    -  high viscosity independence, broad measuring range for each type
  •    -  high medium temperatures and working pressures up to 9137 psi
  •    -  linearisation in the measuring instrument
  •    -  detection of flow direction, arbitrary mounting position and connectors
  •    -  measuring of quantities possible (metering)
  •    -  viscosity min. 5 mm2/s (cSt)
  •    -  high measuring accuracy


Technical:


QG 100 Frequency (ISDS)

  •    -  circular connectors M16 x 0.75 with screw-locking Layout 06-a, 6 poles, male IEC / DIN EN 61076-2-106

QG 110 4…20 mA 2-wire (ISDS)

  •    -  circular connectors M16 x 0.75 with screw-locking Layout 06-a, 6 poles, male IEC / DIN EN 61076-2-106

Available in several flow ranges from 0.005 to 300 LPM.

 Frequency  4-20 mA
 part number connection range  part number connection range
 3143-01-35.030 G1/4" 0.005…1lpm  3185-01-35.030 G1/4" 0.005…1lpm
 3143-02-35.030 G1/4" 0.05…5lpm  3185-02-35.030 G1/4" 0.05…5lpm
 3143-03-35.030 G3/8" 0.2…30lpm  3185-03-35.030 G3/8" 0.2…30lpm
 3143-04-35.030 G3/4" 0.7…70lpm  3185-04-35.030 G3/4" 0.7…70lpm
 3143-05-35.030 G1 1/4" 3.0…300lpm  3185-05-35.030 G1 1/4" 3.0…300lpm 

 


 

 

 

Accessories and Spare parts.

 part number  description
 8824-S1-02.50S  measuring cable frequency / 4…20mA / ISDS (standard) 2.5m  with and without ISDS, M16 6-pole connector – 6-pole M16 socket
 8824-S1-05.00S  measuring cable frequency / 4…20mA / ISDS (standard) 5m  with and without ISDS, M16 6-pole connector – 6-pole M16 socket
 3403-xx-S-E5.37  pressure sensor  HySense PR 100, 4…20mA, IP67 (click here for range)
 34P3-xx-S-01.37A2  pressure sensor  HySense PR 400, 4…20mA, IP67 (click here for range)
 3408-22D0-D631Z1S  temperature sensor  HySense TE 300, 4…20mA, IP67, -50…+200°C
 2103-07-18.62N  direct connection straight  MINIMESS® series 1620, ISO228-G ¼“ female