Hydrotechnik home

DATA SHEETS
Data Recorders
MS 8050
Manual
PR 100
QT 500
TE 300

8050 p/p/T/Q

The MultiSystem 8050 is also an easy to control unit. It has a total of 32 channels (optional 40), clear display, and a large number of measured values that can be presented easily. This makes the MultiSystem 8050 an ideal instrument for measurements at complex systems. Six output channels offer even more possibilities.

BENEFITS

  •    -  suitable for complex measurements: Up to 30 channels, optionally 40, shown on one TFT display at the same
  •    -  clear and user-friendly: touchscreen display and logical menu structure
  •    -  live-analysis of the measured data: perfect line charts on the huge monitor
  •    -  universal possibilities for applications: analogue and digital inputs and outputs, diverse interfaces

 



MS 8050
 MS8050 - technical data
 Analogue inputs 8x standard, 2x HighSpeed (with ISDS)
... input signal 0/4 ... 20 mA, 0 ... 10 V ± 10 V
... resolution A/D-converter 16 bit
... Meas. rate HighSpeed 10,000 values per second
... Meas. rate standard 1,000 values per second
... error limit ± 0.1 % FS
 Frequency input 4x (with ISDS)
... input frequency 0.25 Hz ... 5 kHz WDD, 0.25 Hz ... 20 kH WOD
... error limit ± 0.02 % MV
 Sensor connectors 6-pin, M16 x 0.75
 Digital input 4, one galvanically isolated
 Digital output 4x
 Analogue output 2x
 Special channels 6x,(optionally 14)
... calculations difference, sum, hydraulic power, CAN, ...
... free definable formulas yes
 CAN measuring rate 100 values per second
... CAN protocols CANopen, SAE J1939, ...
 Filter functions Hardware- (low-pass) and several software filters
 Internal data memory SD-card 256 MB, expandable to 1 GB
... number of series of meas. 200
... scan rate 0.1 ms to 99 min
 Trigger 2x, selectable
 Display / Resolution 10.4“ Colour TFT Touch panel / 800x600
 Interface RS 232, USB, CAN, Centronics, LVDS
 Mains operation power supply 24VDC/1,8A
 Fusing self-reversing fuse resistors
 Sensor power supply 12 VDC
 Operation temperature 0 ... 60 °C at < 80% relative humidity
 Storage temperature -20 ... +60 °C
 Dimensions (L x W x H) ~ 310 x 254 x 60 mm
 Weight ~ 3,1000 g
 Protection type IP 40

 

Pressure Sensor Ordering Code

 Pressure range  * Replace XX with
 0...600 bar (0...8700 psi)  18
 0...400 bar (0...5800 psi)  15
 0...200 bar (0...2900 psi)  10
 0...60 bar (0...870 psi)  21
 -1...+6 bar (-14...87 psi)  32


Flow Turbine Ordering Code

 Flow range  * Replace YY with
1 to 10 l/min  01
2 to 75 l/min  70
9 to 300 l/min  71
16 to 600 l/min  72
   

PR100 ISDS pressure sensors and QT100 flow turbines supplied with calibration certificate traceable to national standards