Hydrotechnik home
Multihandy 2025
The MultiHandy 2025 datalogging kit with ISDS pressure sensors and flow meters allows the engineer to carry out thorough tests. Please choose your pressure sensors of choice from the tables below.
Pressure Kit contains:
- - 2 x PR109 ISDS pressure sensors with integrated 2.5m long moulded instrument cable
- - 2 x Minimess 1620 female test point to sensor adaptors
- - universal mains USB charger with USB download cable
- - printed Quick Start Manual
- - CD ROM with HYDROcom 6 software and full user manual
MS4070 - technical data |
analogue inputs(selectable) |
up to 2x (with ISDS) |
... input signal |
0/4 ... 20 mA 0/2 ... 10 V |
... resolution A/D-converter |
12 bit |
... measuring rate |
1 ms |
... error limit |
± 0.2 % of full scale |
frequency input(selectable) |
up to 2x (with ISDS) |
... input frequency |
1 Hz ... 5 kHz |
... error limit |
± 0.1 % MW |
sensor connectors |
6-pin, M16 x 0.75 |
internal data memory |
120,000 measured values per series |
... number of series of meas. |
5xxx |
... scan rate |
1 ms / 10 ms / 100 ms / 1 s / 10 s |
display |
2.6“ B/W-LCD |
interface |
USB |
power supply |
USB / NiMH (2*AA) 2.4 V / 2700 mAh |
... battery operation |
10h - 2 sensors with 12 mA load |
operation temperature |
-10 ... 60 °C at < 80% relative humidity |
storage temperature |
-20 ... +70 °C |
dimensions (L x W x H) |
201 x 90 x 52.5 mm |
weight |
~ 330 g |
protection type |
IP 40 |
BENEFITS
- - user friendly device - Connect - Switch on - Measure
- - a bright sunlit screen viewable in dull conditions
- - easily diagnose hydraulic faults with changing pressures and flows
Pressure Sensor Ordering Code
Pressure range |
* Replace XX with |
0...600 bar (0...8700 psi) |
18 |
0...400 bar (0...5800 psi) |
15 |
0...200 bar (0...2900 psi) |
10 |
|