Linde home
HPR-02
Displacement size from 55 to 165D
SELF-REGULATING PUMP FOR OPEN CIRCUIT OPERATION
- - optimum interaction with Linde LSC control valves and LinTronic
- - energy saving operation by ‘flow on demand’-control
- - dynamic response
- - excellent suction up to rated speed
- - noise optimization over the whole range of operation
- - compact design
- - high power density
- - high reliability
- - long working life
Design characteristics
- - axial piston pump in swashplate design for high pressure open circuit systems
- - clockwise or counter clockwise rotation
- - self-priming at high nominal speed
- - tank pressurization or swash angle reduction for high speed applications
- - adaptive noise optimization SPU
- - decompression fluid is discharged via pump housing to keep suction side calm
- - exact and robust load sensing controllers with or without swash plate position feedback
Controls
- - LP load sensing with pressure cut-off
- - H1L load sensing with hydraulic ΔpLS – override
- - E1L load sensing with electrical ΔpLS – override
- - LEP load sensing with electric stroke limiter and pressure cut-off
- - ETP electro-proportional with hyperbolic power-limiter and pressure cut-off
- - TL2 load sensing with hyperbolic power limiter
Technical Data
HPR-02 |
|
55 |
75 |
95 |
105 |
135 |
165 |
210 |
249 |
280 |
105D |
125D |
165D |
Max. displacement |
cc/rev |
55 |
75.9 |
94.7 |
105 |
135.7 |
165.6 |
210.1 |
249.9 |
281.9 |
210 |
252 |
331.2 |
Max. operating speed (without tank pressurization) |
rpm |
2700 |
2500 |
2500 |
2500 |
2350 |
2200 |
2100 |
2300² |
2000 |
2450 |
2400 |
2150 |
Max. oil flow* |
l/min |
148.5 |
189.8 |
237.5 |
262.5 |
318.9 |
364.3 |
441.2 |
574.8² |
563.8 |
514.5 |
604.8 |
712.1 |
Nominal pressure |
bar |
420 |
420 |
350 |
420 |
420 |
420 |
420 |
350 |
420 |
420 |
380 |
420 |
Max. pressure** |
bar |
500 |
500 |
420 |
500 |
500 |
500 |
500 |
420 |
500 |
420 |
500 |
500 |
Torque (Δp=430 bar; charge pressure=20 bar) |
Nm |
368 |
507 |
528 |
702 |
907 |
1107 |
1404 |
1392 |
1884 |
1245 |
1404 |
1964 |
Max. housing pressure |
bar |
2.5 |
2.5 |
2.5 |
2.5 |
2.5 |
2.5 |
2.5 |
2.5 |
2.5 |
2.5 |
2.5 |
2.5 |
Corner power |
KW |
104 |
132.8 |
138 |
183.8 |
223.2 |
255 |
308.8 |
335.3² |
394.7 |
360.2 |
383 |
431.8 |
Weight approx. (without oil)*** |
kg |
39 |
39 |
44.5 |
50 |
65 |
89 |
116 |
125 |
165 |
96 |
113 |
177 |
*theoretical data of a single unit without efficiency effects **highest transient pressure, that can temporarily occur |
|
|
|
|
|
|
|
|
|
|
|
|
|
|