Hydrotechnik home
5070 p/p/T/Q Pressure, Temperature & Flow Measuring Kit
The MultiSystem 5070 is the latest generation in the Multi-System range from Hydrotechnik GMBH. Ideal for mobile application the 5070 boasts 40 channel capability.
8 direct input channels and 32 special channels ( for calculation and CAN ). Internal storage memory for up to 500 measurements with up to 6 million measuring values per measurement. The 5070 comes with a new graphical interface allowing for easier user menu navigation. Powering the device is a new Lithium Ion battery allowing for whole day recording ( depending on number of sensors connected ) and quick charging function to recharge efficiently in under 2 hours. Input signal frequency from 0.25 to 20,000 kHz. The display which can show graphics, which allows you to analyze your measurement while recording the data. With a USB-stick you can transfer the data quickly from the instrument to your pc. Online measurements are also possible. With its various interfaces as well as CAN-Bus, the MultiSystem 5070 offers many benefits.
New for the 5070 is the addition of a seperate CAN interface bringing the available CAN channels to 32 through 2 seperate CAN inputs.
As with all the datarecorders in the range the 5070 is also available within a newly designed measurement equipment case.
ISDS ( Intelligent Sensor Detection System ) - automatic detection of ISDS sensors calibration, range and type by Hydrotechnik compatible data recorders.
Complete Measuring kit containing
- - 1 Measuring instrument Multi-System 5070
- - 1 Country Specific Power pack 24 VDC with adaptor
- - 1 USB data transmission cable
- - 2 MINIMESS® direct connectors 1620
- - 1 Software HYDROcom6 (full)
- - 1 ISDS Temperature sensor -50 °C to +200 °C
- - 2 ISDS Pressure sensor HT-PD with free selectable measuring range
- - 1 ISDS Flow Measuring turbine with free selectable measuring range
- - 1 ABS Transportation case
- - 4 Measuring cables 5.0 m
Technical data |
Analogue inputs |
8x (with ISDS) 6x Analogue, 2x switchable |
... input signal |
0/4 ... 20 mA, 0/2 ... 10 V, 1...5 V, 0.5 ... 4.5 V, ± 10 V |
... resolution A/D-converter |
13 bit |
... Meas. rate HighSpeed |
10,000 values per second |
... Meas. rate standard |
1,000 values per second |
... error limit |
± 0.15 % FS |
Frequency input |
2x (with ISDS) |
... input frequency |
0.25 Hz ... 20 kHz (w.o.D.), 0.25 Hz ... 5 kHz (w.D.) |
... measuring rate |
10 ns |
... error limit |
± 0.02 % MV |
Sensor connectors |
6-pin, M16 x 0.75 |
Digital input |
1x, galvanically separated, 3.5 ... 30 VDC |
... measuring rate |
1,000 values per second |
Digital output |
1x |
... max. load |
Ub / 10 mA |
... reaction time |
≤ 1 ms |
Special channels |
32x |
... calculations |
difference, sum, hydraulic power, CAN, ... |
... free definable formulas |
yes |
CAN measuring rate |
100 values per second |
... CAN protocols |
CAN, CANopen, SAE J1939, ... |
Filter functions |
Hardware- (low-pass) and several software filters |
Internal data memory |
6 million analogue per series |
... number of series of meas. |
500 |
... scan rate |
1 ms |
Trigger |
4x, linkable (bigger, smaller, falling/rising edge) |
... Pretrigger |
0 / 10 / 20 / ... 100 % |
Display / Resolution |
5“ Colour TFT / QVGA (320 x 240) |
Interface |
USB 2.0 device, USB 2.0 host, RS 232 |
Power supply |
power pack or Lithium Ion battery 7.2V, 5.8Ah |
... battery operation |
max. 10h |
Mains operation power supply |
12 ... 30 VDC |
Sensor power supply |
13 (battery operation) ... 22 (mains operation) VDC, 100 mA |
CAN / MX power supply |
Vs+ VDC, 180 ... 200 mA |
Operation temperature |
-10 ... 50 °C at < 80% relative humidity |
Storage temperature |
-20 ... +70 °C |
Dimensions (L x W x H) |
~ 270 x 140 x 69 mm |
Weight |
~ 1,277 g |
Protection type |
IP 40 |
BENEFITS
- - Easy to handle: flexible, logical menu structure and keypad
- - Display: huge, high-definition color display with for clear images
- - Live-analysis of the measured data: perfect line charts with zoom-function
- - Efficient: fast 32-bit processor, long-lasting battery data collections with 6.000.000 measured values, max. 10 hours battery-supplied operation
- - Fast: Quick connection with USB 2.0
- - Premium housing: light, but impact-proof housing with strong pins/access
- - Tool for diagnosis: full diagnosis for average and high complex systems, 40 channels free for defined measurements
- - Universal possibilities for applications: analogue and digital inputs and outputs, diverse interfaces
Measuring Kit Part Code:
5070 p/p/T/Q-xx-xx-yy*
Pressure Sensor Ordering Code
Pressure range | * Replace XX with |
0...600 bar (0...8700 psi) |
18 |
0...400 bar (0...5800 psi) |
15 |
0...200 bar (0...2900 psi) |
10 |
0...60 bar (0...870 psi) |
21 |
-1...+6 bar (-14...87 psi) |
32 |
Flow Turbine Ordering Code
Flow range | * Replace YY with |
1 to 10 l/min |
01 |
2 to 75 l/min |
70 |
9 to 300 l/min |
71 |
16 to 600 l/min |
72 |
PR100 ISDS pressure sensors and QT100 flow turbines supplied with calibration certificate traceable to national standards
|