4070 p/p/T/Q Pressure, Temperature & Flow Measuring Kit

The MultiSystem 4070 replaces the MS4010.


Ideal for mobile application the 4070 boasts 17 channel capability with a 3.5" coloured display. 5 direct input channels, 10 special channels ( for calculation and CAN ), and digital input and output. Internal storage memory for up to 100 measurements with up to 2 million measuring values per measurement.

The 4070 comes with a new graphical interface allowing for easier user menu navigation.

Powering the device is a new Lithium Ion battery allowing for whole day recording ( depending on number of sensors connected ) and quick charging function to recharge efficiently in under 3 hours.

Input signal frequency from 0.25 to 20 kHz. The display which shows graphics, can analyze your measurement while recording the data. With a USB-stick you can transfer the data quickly from the instrument to your pc. Online measurements are also possible. With its various interfaces as well as CAN-Bus, the MultiSystem 4070 offers many benefits.

As with all the datarecorders in the range the 4070 is also available within a newly designed measurement equipment case.

BENEFITS

MS 4070
  •    -  easy to handle: flexible, logical menu structure and keypad
  •    -  display: huge, high-definition color display with for clear images
  •    -  live-analysis of the measured data: perfect line charts with zoom-function
  •    -  efficient
  •    -  32-bit processor
  •    -  long-lasting battery, max. 10 hours battery-supplied operation
  •    -  data collections with 2.000.000 measured values
  •    -  fast: quick connection with USB 2.0
  •    -  premium housing: light, but impact-proof housing with strong pins/access
  •    -  tool for diagnosis: full diagnosis for average and high complex systems, 10 channels free for defined measurements
  •    -  universal possibilities for applications: analogue and digital inputs and outputs, diverse interfaces

 

 MS4070 - technical data
 analogue inputs 3x/4x (1x configurable )
... input signal 0/4 ... 20 mA, 0/2 ... 10 V, 1...5 V, 0.5 ... 4.5 V, ± 10 V
... resolution A/D-converter 13 bit
... meas. rate HighSpeed 10,000 values per second
 frequency input 1x/2x ( 1x configuarable )
... input frequency 0.25 Hz ... 20 kHz (w.o.D.), 0.25 Hz ... 5 kHz (w.D.)
... error limit ± 0.02 % MV
 sensor connectors 6-pin, M16 x 0.75
 digital input 1x, galvanically isolated, 2 ... 30 VDC
 digital output 1x
... max. load Ub / 10 mA
... reaction time ≤ 1 ms
 special channels 10x
... calculations difference, sum, hydraulic power, CAN, ...
... free definable formulas yes
 CAN measuring rate 100 values per second
... CAN protocols CAN, CANopen, SAE J1939, ...
 internal data memory 2 million analogue per series
... number of series of meas. 100
... scan rate 1 ms
 display / resolution 3.5“ Colour TFT / QVGA (320 x 240)
 interface USB 2.0 device, RS 232
 power supply power pack or Lithium Ion battery 7.2V, 5.8Ah
... battery operation max. 10h
 mains operation power supply 12 ... 30 VDC
 operation temperature -10 ... 50 °C at < 80%  relative humidity
 storage temperature -20  ... +70  °C
 dimensions (L x W x H) ~ 270 x 140 x 69 mm
 weight ~ 0,795 g
 protection type IP 40

 

Complete Measuring kit containing:

  •       - 1 measuring instrument Multi-System 4070
  •       - 1 country Specific Power pack 24 VDC with adaptor
  •       - 1 USB data transmission cable
  •       - 2 MINIMESS® direct connectors 1620
  •       - 1 software HYDROcom 6(full)
  •       - 1 temperature sensor -50 °C bis +200 °C
  •       - 2 ISDS Pressure sensor HT-PD with free selectable measuring range
  •       - 1 ISDS Flow Measuring turbine with free selectable measuring range
  •       - 1 ABS Transportation case
  •       - 4 measuring cables 5.0 m 

Measuring Kit Part Code:

4070 p/p/T/Q-xx-xx-yy*

Pressure Sensor Ordering Code

 Pressure range  * Replace XX with
 0...600 bar (0...8700 psi)  18
 0...400 bar (0...5800 psi)  15
 0...200 bar (0...2900 psi)  10
 0...60 bar (0...870 psi)  21
 -1...+6 bar (-14...87 psi)  32


Flow Turbine Ordering Code

 Flow range  * Replace YY with
1 to 10 l/min  01
2 to 75 l/min  70
9 to 300 l/min  71
16 to 600 l/min  72
   

PR100 ISDS pressure sensors and QT100 flow turbines supplied with calibration certificate traceable to national standards